ISO 15693 and ISO 18000-3 operation
Supports 13.56 MHz HF RFID, anti-collision processing and up to 50 tags/s for host-controlled or scanning workflows.

13.56 MHz medium-power HF reader module | MCX antenna interface

Supports 13.56 MHz HF RFID, anti-collision processing and up to 50 tags/s for host-controlled or scanning workflows.
With a suitable external antenna, the reference read range is up to 65 cm. Actual range depends on the antenna, cards or tags, RF settings and equipment structure.
Configurable medium-power output and an MCX antenna interface allow the module to be designed into purpose-built HF reading equipment.
The PCB and sheet-metal structure weighs approximately 31 g and uses RS232 communication with 12 V DC power.

RU6722 Reader Writer Module
| Frequency | 13.56 MHz |
|---|---|
| Protocols | ISO 15693 and ISO 18000-3 |
| Read rate | Up to 50 tags/s |
| Reference range | Up to 65 cm with a suitable external antenna |
| RF output | 0.25-1.5 W, configurable |
| Anti-collision | Supported |
| Noise detection | Supported |

RU6722 Reader Writer Module
| Antenna interface | MCX |
|---|---|
| Communication | RS232 |
| Operating modes | Host control and scanning, software configurable |
| Energy saving | Automatic RF shutdown when idle |
| Power input | 12 V DC, no more than 400 mA; the current specification contains a DV/DC notation discrepancy that requires confirmation |
| Maximum power consumption | 3.5 W |

RU6722 Reader Writer Module
| Dimensions | 73 x 45 x 8.5 mm |
|---|---|
| Gross weight | Approximately 31 g |
| Construction | PCB and sheet metal |
| Water protection | Not rated for water exposure |
| Operating temperature | -20°C to +60°C |
| Storage temperature | -40°C to +85°C |
| Relative humidity | 10%-95% RH, non-condensing |
| Unspecified fields | Peripheral crosstalk and anti-metal design are not currently specified. These fields are not interpreted as zero or as supported capabilities. |
|---|

RU6722 Reader Writer Module

Project configuration, certification and final specifications are subject to the confirmed quotation and technical agreement.